The Von Duprin 98/99 Series offers durable, high-quality push pad exit devices designed for heavy-duty commercial applications, suitable for single or double doors in various materials․
1․1 Overview of the Von Duprin 98/99 Series
The Von Duprin 98/99 Series includes a range of exit devices designed for heavy-duty commercial applications․ Models such as the 98/99 Rim Exit Devices, 98/99-F, CD98/99, QEL98/99, and HH/HW98/99 cater to different door configurations and requirements․ Known for their durability and versatility, these devices are suitable for single or double doors in various materials, including wood, aluminum, and hollow metal․ The series offers push pad, rim, and vertical rod options, ensuring compatibility with diverse architectural needs․ Specialized models like the hurricane-rated HH/HW devices provide enhanced security for extreme conditions, while options like electric latch pull (EL) and battery backup (BB) add flexibility․ Installation instructions and resources, including QR codes for digital guides, are available to ensure proper setup․
1․2 Key Features and Applications
The Von Duprin 98/99 Series is engineered with robust features, including push pad operation, heavy-duty construction, and versatile mounting options․ These exit devices are ideal for high-traffic commercial environments, such as schools, hospitals, and retail spaces․ They support single and double door installations and are compatible with wood, aluminum, and hollow metal doors․ Key features include hurricane-rated models (HH/HW), electric latch pull (EL), and battery backup (BB) options․ These devices ensure safety, functionality, and reliability, making them suitable for a wide range of applications requiring secure and efficient door operation․
Preparing for Installation
Proper preparation ensures a smooth installation process․ Gather all required tools, materials, and review the installation manual thoroughly․ Use the provided screw chart for accurate hardware selection․
2․1 Required Tools and Materials
To ensure a successful installation, gather all necessary tools and materials beforehand․ Required tools include a drill with bits, screwdrivers, and wrenches․ Materials needed are specified screws, through-bolts for hurricane-rated models, and strike templates․ Refer to the screw chart provided in the manual for precise hardware selection․ Additional items like a QR code scanner for digital instructions may enhance the process․ Ensure all components are compatible with your specific Von Duprin 98/99 model․ Proper preparation prevents delays and ensures compliance with manufacturer guidelines․ Always consult the manual for model-specific requirements․
2․2 Reading the Installation Manual
Thoroughly reading the installation manual is essential for a successful setup․ It provides detailed step-by-step instructions, tool requirements, and hardware specifications․ Pay attention to model-specific details, such as hurricane-rated devices needing through-bolts․ The manual also includes screw charts and alignment guides to ensure proper installation․ For convenience, some manuals offer QR codes linking to interactive digital instructions․ Failure to follow the manual may result in installation issues or safety hazards․ Always review the document carefully before starting the process to avoid errors and ensure compliance with manufacturer guidelines․
Installation Process
The installation process involves preparing the door, aligning components, and securing the exit device․ Use templates for accuracy and follow manual guidelines to ensure proper setup․
3․1 Door Preparation and Alignment
Proper door preparation and alignment are critical for a successful installation․ Begin by marking the door’s finish height and drawing horizontal center lines for both the exit device and strike․ For double doors with a mullion, use the existing strike center line as a reference․ Align the strike on the center line and mark the slotted holes․ Use the provided templates to ensure accurate placement and avoid misalignment․ Double-check all measurements before drilling to prevent errors․ Proper alignment ensures smooth operation and longevity of the exit device․ Hurricane-rated models require through bolts for added security․
3․2 Strike Installation and Adjustment
Install the strike by drilling pilot holes and securing it with screws․ For hurricane-rated models, use through bolts for added stability․ Align the strike hook with the latch bolt to ensure proper engagement․ Adjust the strike screws to achieve precise alignment and smooth operation․ After installation, test the latch bolt to ensure it clears the floor and aligns with the strike․ Proper adjustment is essential for reliable performance and durability of the exit device․ Regular checks and minor adjustments may be needed over time to maintain functionality․ Always refer to the installation manual for specific guidance․
Specific Device Considerations
Considerations include hurricane-rated models requiring through bolts, electric latch pull options, and battery backup systems for enhanced functionality and compliance with specific building codes․
4․1 Hurricane-Rated Devices (HH/HW Models)
The Von Duprin HH/HW models are designed for extreme weather conditions, requiring through-bolts for added strength and durability․ These devices meet stringent hurricane standards, ensuring resistance to high winds and impacts․ Installation must follow specific guidelines to maintain their Wind and Impact ratings, with through-bolts mandatory for secure mounting․ Proper alignment and tightening ensure optimal performance and safety in harsh environments, complying with local building codes and regulations for hurricane-prone areas․ Always refer to the manual for precise instructions to guarantee reliability and structural integrity․
4․2 Electric Latch Pull (EL) and Battery Backup (BB) Options
The Electric Latch Pull (EL) and Battery Backup (BB) options enhance functionality and reliability․ The EL feature provides smooth, consistent latch operation, ideal for high-traffic areas․ The BB option ensures continued functionality during power outages, supporting 24VDC systems․ Installation requires wiring the solenoid to a PS873 logic board, with specific considerations for voltage and current․ For the 900-BB model, disconnect AC power before installation to avoid shock risks․ These options integrate seamlessly with Von Duprin exit devices, offering advanced security and convenience while maintaining compliance with electrical standards․ Proper setup ensures optimal performance and safety․
Troubleshooting Common Issues
Identify and address misalignment, electrical malfunctions, or improper screw usage․ Verify strike alignment and latch bolt clearance․ Test functionality post-installation to ensure smooth operation and reliability․
5․1 Identifying and Solving Installation Problems
Common issues during Von Duprin 98/99 installation include misalignment of the strike and latch bolt, improper screw usage, or electrical malfunctions․ Start by verifying the alignment of the door and strike, ensuring the center lines match․ Check for obstructions or uneven surfaces that may affect proper latching․ For electrical issues, ensure all wires are securely connected and the power supply is correctly configured․ Refer to the screw chart for the correct hardware, and consider consulting the manual or contacting a professional if problems persist․ Proper adjustment and testing are critical for reliable operation․
5․2 Post-Installation Testing and Quality Checks
After installation, perform thorough testing to ensure proper functionality․ Check the latch bolt operation, door alignment, and strike engagement․ Verify smooth operation of the push pad and ensure no resistance is felt․ For electrified models, test the latch retraction and battery backup functionality․ Confirm all screws are securely tightened and the device is properly aligned․ Conduct a visual inspection to ensure all components are correctly installed․ Testing confirms the device meets safety standards and operates reliably, providing secure and efficient egress․ Regular quality checks ensure long-term performance․
Maintenance and Upkeep
Regular maintenance ensures the longevity and functionality of Von Duprin 98/99 devices․ Inspect components for wear, clean moving parts, and lubricate hinges and latches․
6․1 Routine Maintenance Tasks
To maintain Von Duprin 98/99 devices, inspect all components for wear and tear․ Clean and lubricate hinges, latches, and rods regularly․ Check strike alignment and tighten screws if necessary․ For electric latch pull (EL) models, ensure proper battery function and test backup systems․ Lubricate moving parts annually with a silicone-based spray to prevent corrosion․ Replace worn or damaged components promptly to ensure smooth operation․ Regularly test the exit devices to confirm they function correctly under all conditions, including emergency scenarios․ Always refer to the installation manual for specific maintenance recommendations tailored to your device model․
6․2 When to Contact a Professional
If issues arise beyond routine maintenance, such as faulty electric latch pulls or strike misalignment, contact a certified professional․ For hurricane-rated devices, ensure only authorized personnel perform adjustments․ If troubleshooting doesn’t resolve problems, or if complex repairs are needed, seek expert assistance․ Von Duprin recommends consulting their support network for specialized tools and knowledge, especially for integrated systems or advanced features․ Professional intervention ensures compliance with safety standards and optimal device performance․ Always refer to the installation manual for guidance on when expert help is required․
Proper installation and maintenance of Von Duprin 98/99 Series devices ensure long-term reliability and safety․ Adhering to the manual guarantees optimal performance and compliance with industry standards․
7․1 Summary of Key Installation Steps
The successful installation of Von Duprin 98/99 Series devices involves several critical steps․ First, ensure all tools and materials are prepared, including screws, templates, and drills․ Align the device and strike center lines carefully, marking holes for accurate placement․ Drill pilot holes and install screws as specified in the screw chart․ For hurricane-rated models, use through bolts for added security․ After installation, test the latch bolt to ensure proper functionality․ Finally, double-check all alignments and tighten screws securely․ Always refer to the manual for detailed guidance and specific model requirements․ Proper execution ensures reliability and safety․
7․2 Importance of Proper Installation
Proper installation of Von Duprin 98/99 Series devices is essential for ensuring safety, functionality, and compliance with regulations․ Misaligned or improperly secured components can lead to mechanical failures, compromising emergency exits and potentially violating building codes․ Correct installation enhances durability, reduces maintenance needs, and ensures smooth operation during emergencies․ Adhering to the provided instructions guarantees optimal performance and reliability, making it crucial to follow each step meticulously․ Always prioritize precision and adherence to guidelines for a secure and efficient setup․ Proper installation safeguards users and maintains the device’s longevity and effectiveness․
Frequently Asked Questions (FAQ)
This section addresses common inquiries about the Von Duprin 98/99 Series, providing clarity on installation, troubleshooting, and maintenance to ensure smooth operation and compliance․
8․1 Common Questions About the 98/99 Series
The Von Duprin 98/99 Series is a popular choice for commercial exits due to its durability and versatility․ Users often ask about compatibility with different door materials, such as wood, aluminum, or hollow metal․ Another common inquiry is regarding the difference between rim, surface-mounted, and concealed vertical rod devices․ Many also seek clarification on hurricane-rated models and the use of through bolts for added security․ Additionally, questions about electric latch pull and battery backup options are frequent, ensuring proper functionality in various settings․ Proper installation and maintenance are also key topics․
8․2 Clarifying Technical Specifications
The Von Duprin 98/99 Series includes models like the HH/HW98/99, designed for hurricane-rated applications, requiring through bolts for enhanced security․ Devices are compatible with wood, aluminum, or hollow metal doors․ The series offers rim, surface vertical rod, and concealed vertical rod options․ Electrical specifications include 24V DC operation with a 16A inrush current․ QR codes are provided for smartphone-friendly digital instructions․ Ensure compliance with local building codes and standards for proper installation and functionality․ Always refer to the official manual for detailed technical details and safety guidelines․